Features
- ■ Henka Braid
- ■ Atraumatic processed round tip
- ■ 0.71″ inner lumen (6Fr)
- ■ Unique 3rd curve
- ■ Reinforced 2nd curve
- ■ Hyper Shaft
- ■ 100cm working length
- ■ Available in 6F, 7F and 8F
Benefits
- ■ Large, smooth inner lumen reduces insertion resistance and friction between devices
- ■ Flexible tip aids improved atraumatic vessel engagement and correct positioning
- ■ The Hyper Shaft prevents reduction of manoeuvrability within vessel
- ■ Offers long lasting back-up due to reinforced 2nd curve and unique 3rd curve increasing
the contact area between the catheter and the aortic wall - ■ HENKA-Braid unique braiding technology provides superior manoeuvrability in tortuous vessels
- ■ Full range of shapes provided
► The reasonable specifications for your stable PCI procedure
■ Enough room for your needs
The large inner diameter diminishes the worry about friction between devices especially with 6F KBT, and provides more effective contrast visualization.
■ PTFE liner
Smooth inner lumen reduces device insertion resistance.
► The reasonable specifications for your stable PCI procedure
■ Material
- Safe engagement is made possible due to the Urethane tip, the same material used for the tip of ASAHI Corsair, providing both flexibility and high visualization.
■ All round processed tip
- Processed round tip walls result in atraumatic vessel engagement.
Processed Round Tip
Processed round tip walls result in atraumatic vessel engagement
Conventional Guide Catheter |
Hyperion Guide Catheter with processed round tip |
► Long-lasting backup even during challenging procedures
■ Hyper Shaft
ASAHI INTECC’s unique processing technologies prevent reduction of maneuverability and backup due to heat and moisture of blood during the procedure.
■ Reinforced 2nd curve
A reinforced 2nd curve and excellent shape retention are key factors for high backup.
■ ASAHI INTECC-original 3rd curve
ASAHI Hyperion’s unique 3rd curve at the proximal part of the 2nd curve, improves backup by increasing the contact area between the catheter and the aortic wall.
*For JL, JLST, AL, SAL
Original 3rd Curve
ASAHI Hyperions unique 3rd curve at the proximla part of the 2nd curve, improves backup by increasing the contact area between the catheter and the aortic wall
► Provides superior maneuverability in tortuous vessels and prevents the catheter from jumping out of the ostium when engaging.
■ HENKA-Braid
ASAHI INTECC’s unique braiding technology provides well-balanced shaft with reinforced supportive shaft that gradually becomes softer towards the tip.
* HENKA is a Japanese word for transformation
Number of side holes: 2
Not all shapes and sizes are available in all markets. Please check availability with your sales representative.
“ASAHI”, “ASAHI Hyperion” and “Corsair” are trademarks or registered trademarks of ASAHI INTECC CO., LTD. in Japan and other countries.